Page #232 background image
Configuring Link Traps and Link Flap Detection set linkflap downtime
4-46 Port Configuration
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Examples
Thisexampleshowshowtosetthelinkflapthresholdonportfe.1.4to5:
Matrix(rw)->set linkflap threshold fe.1.4 5
set linkflap downtime
Usethiscommandtosetthetimeinterval(inseconds)oneormoreportswillbehelddownaftera
linkflapviolation.
Syntax
set linkflap downtime port-string downtime_value
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Examples
Thisexampleshowshowtosetthelinkflapdowntimeonportfe.1.4to5000seconds:
Matrix(rw)->set linkflap downtime fe.1.4 5000
portstring Specifiestheport(s)onwhichtosetthelinkflapactiontriggercount.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage 42.
threshold_value Specifiesthenumberoflinkdowntransitionsnecessarytotriggerthe
linkflapaction.
portstring Specifiestheport(s)onwhichtosetthelinkflapdowntime.Fora
detaileddescriptionofpossibleportstringvalues,refertoPortString
SyntaxUsedintheCLIonpage 42.
downtime_value Specifiesadowntimeinseconds.Avalueof0willsetthedowntimeto
forever.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals