set radius accounting Configuring RADIUS
Enterasys Matrix DFE-Gold Series Configuration Guide 25-57
Defaults
Ifnoparametersarespecified,allRADIUSaccountingconfigurationinformationwillbe
displayed.
Mode
Switchcommand,ReadOnly.
Example
ThisexampleshowshowtodisplayRADIUSaccountingconfigurationinformation.Inthiscase,
RADIUSaccountingisenabledandglobaldefaultsettingshavenotbeenchanged.Oneserverhas
beenconfigured.TheEnterasysMatrixSeriesdeviceallowsforupto10RADIUSaccounting
serverstobeconfigured,withupto2active
atanygiventime.
FordetailsonenablingandconfiguringRADIUSaccounting,refertosetradiusaccountingon
page 2557:
Matrix(rw)->show radius accounting
Accounting state: Enabled
Accounting update interval: 1800 secs
Accounting interval minimum: 600 secs
Server Server Acct
Index IP Port Retries Timeout Status
-----------------------------------------------------------------
1 1.1.1.1 1236 2 5 Primary
set radius accounting
UsethiscommandtoconfigureRADIUSaccounting.
Syntax
set radius accounting {[enable] [disable] [intervalminimum value] [updateinterval
value] [retries retries] [timeout timeout] [server {index | all} ip_address port
[server-secret]
Parameters
enable|disable EnablesordisablestheRADIUSaccountingclient.
intervalminimum
value
SetstheminimumintervalatwhichRADIUSaccountingwillsend
interimupdates.Validvaluesare 60‐2147483647.
updateintervalvalue SetsthenumberofsecondsbetweeneachRADIUSaccountinginterim
update(whenaccumulatedaccountingdataissenttotheserverfor
a
session.)Validvaluesare180‐2147483647.
retriesretries SetsthemaximumnumberofattemptstocontactaspecifiedRADIUS
accountingserverbeforetimingout.Validretryvaluesare1‐
2147483647.
timeouttimeout Setsthemaximum amountoftime(inseconds)toestablishcontactwith
aspecifiedRADIUSaccountingserver
beforetimingout.Validtimeout
valuesare1‐2147483647.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals