Configuring RMON set rmon alarm status
11-22 Network Monitoring Configuration
Defaults
•interval‐3600seconds
•type‐absolute
•startup‐rising
•rthresh‐0
•fthresh‐0
•revent‐0
fevent‐0
•owner‐monitor
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtoconfigurearisingRMONalarm.Thisentrywillconductmonitoring
ofthedeltabetweensamplesevery30seconds:
Matrix(rw)->set rmon alarm properties 3 interval 30 object
1.3.6.1.4.1.5624.1.2.29.1.2.1.0 type delta rthresh 1 revent 2 owner Manager
set rmon alarm status
UsethiscommandtoenableanRMONalarmentry.
Syntax
set rmon alarm status index enable
startuprising|
falling|either
(Optional)Specifiesthetypeofalarmgeneratedwhenthiseventisfirst
enabledas:
Rising‐SendsalarmwhenanRM ONeventreachesamaximum
thresholdconditionisreached,forexample,morethan30collisions
persecond.
Falling‐SendsalarmwhenRMONeventfallsbelowaminimum
thresholdcondition,forexamplewhenthenetworkisbehaving
normallyagain.
•Either‐Sendsalarmwheneitherarisingorfallingthresholdis
reached.
rthreshrthresh (Optional)Specifiesaminimumthresholdforcausingarisingalarm.
fthreshfthresh (Optional)Specifiesamaximumthresholdforcausingafallingalarm.
reventrevent (Optional)Specifiestheindexnumber
oftheRMONeventtobe
triggeredwhentherisingthresholdiscrossed.
feventfevent (Optional)SpecifiestheindexnumberoftheRMONeventtobe
triggeredwhenthefallingthresholdiscrossed.
ownerowner (Optional)Specifiesthenameoftheentitythatconfiguredthisalarm
entry.