Configuring Spanning Tree Bridge Parameters set spantree msti
6-14 Spanning Tree Configuration
set spantree msti
UsethiscommandtocreateordeleteaMultipleSpanningTreeinstance.
Syntax
set spantree msti sid sid {create | delete}
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtocreateMSTinstance2:
Matrix(rw)->set spantree msti sid 2 create
clear spantree msti
UsethiscommandtodeleteoneormoreMultipleSpanningTreeinstances.
Syntax
clear spantree msti sid
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtodeleteMST instance1:
Matrix(rw)->clear spantree msti 1
sidsid SetstheMultipleSpanningTreeID.Validvaluesare1‐4094.
Note: Matrix Series devices will support up to 32 instances with an additional
128 MB of memory installed.
create|delete CreatesordeletesanMSTinstance.
sid Specifiesa multipleSpanningTreeIDtobedeleted.