set inlinepower psetrap Configuring Power over Ethernet (PoE)
Enterasys Matrix DFE-Gold Series Configuration Guide 2-69
Example
ThisexampleshowshowtoresetthePoEmanagementmodeto“realtime”onmodule1:
Matrix(rw)->clear inlinepower management 1
set inlinepower psetrap
UsethiscommandtoenableordisablethesendingofanSNMPtrapmessageforamodule
wheneverthestatusofitsportschanges,orwheneverthemodule’sPoEusagethresholdis
crossed.
Syntax
set inlinepower psetrap {disable | enable} module-number
Parameters
Defaults
Disabled.
Mode
Switchcommand,Read‐Write.
Usage
Themodule’sPoEusagethresholdmustbesetusingthesetinlinepowerthresholdcommandas
describedin“setinlinepowerthreshold”onpage 2‐67.
Example
ThisexampleshowshowtoenablePoEtrapmessagingonmodule1:
Matrix(rw)->set inlinepower psetrap enable 1
clear inlinepower psetrap
UsethiscommandtoresetPoEtrapmessagingforamodu lebacktodefaultstateofdisabled.
Syntax
clear inlinepower psetrap module-number
Parameters
Defaults
None.
disable|enable DisablesorenablesPoEtrapmessaging.
module‐number Specifiesthemoduleonwhichtodisableorenabletrapmessaging.
module‐number SpecifiesthemoduleonwhichtoclearPoEtrapmessaging.