Configuring Power over Ethernet (PoE) clear inlinepower available
2-64 Startup and General Configuration
Parameters
Defaults
None.
Mode
Switchcommand,Read‐Write.
Usage
Ifthetotalpowerwattagevaluesetwiththesetinlinepowerassignedcommand(“set
inlinepowerassigned”onpage 2 ‐66)isgreaterthatthemaximumpowerpercentagespecified
withthiscommand,awarningwilldisplay.Iftheuseroptstoexecutetheseparameters,aratioof
assignedpowerwillbeapplied
toeachmodule.Refertotheshowinlinepoweroutput(“show
inlinepower”onpage 2‐61)forasamplewarningmessage.
Example
Thisexampleshowshowtosetthemaximuminlinepoweravailabletothechassisto70percent:
Matrix(rw)->set inlinepower available 70
clear inlinepower available
Usethiscommandtoresetthepercentageofthetotalpoweravailabletoachassistothedefault
valueof100.
Syntax
clear inlinepower available
Parameters
None.
Defaults
None.
Mode
Switchcommand,Read‐Write.
Example
Thisexampleshowshowtoresetthemaximuminlinepoweravailabletothechassisto100
percent:
Matrix(rw)->clear inlinepower available
max-
percentage
Specifiesthepercentageofmaximumpoweravailable.Validvaluesare
0‐100.