Configuring Spanning Tree Loop Protect Features clear spantree lpthreshold
6-72 Spanning Tree Configuration
Example
ThisexampleshowshowtodisplaythecurrentLoopProtectthresholdvalue:
Matrix(rw)->show spantree lpthreshold
LoopProtect event threshold is set to 4
clear spantree lpthreshold
UsethiscommandtoreturntheLoopProtecteventthresholdtoitsdefaultvalueof3.
Syntax
clear spantree lpthreshold
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtoresettheLoopProtecteventthresholdtothedefaultof3:
Matrix(rw)->clear spantree lpthreshold
set spantree lpwindow
UsethiscommandtosettheLoopProtecteventwindowvalueinseconds.
Syntax
set spantree lpwindow value
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Usage
TheLoopProtectWindowisatimervalue,inseconds,thatdefinesaperiodduringwhichLoop
Protecteventsarecounted.Thedefaultvalueis180seconds.Ifthetimerissetto0,theevent
value Specifiesthenumberofsecondsthatcomprisetheperiodduringwhich
LoopProtectevents
arecounted.Thedefaulteventwindowis180
seconds.