Configuring Multiple Authentication show multiauth session-timeout
27-12 MultiAuth Configuration
Defaults
Ifnoauthenticationtypeisspecified,theidletimeoutvalueisreturnedto300secondsforall
authenticationtypes.
Mode
Switchcommand,ReadWrite.
Examples
Thisexampleshowshowtocleartheidletimeoutsessionvaluesforcepandmacauthentication
types,backtodefaultvalueof300seconds:
Matrix(rw)->clear multiauth idle-timeout cep
Matrix(rw)->clear multiauth idle-timeout mac
Thisexampleshowshowtocleartheidletimeoutsessionvaluesforallauthenticationtypes,back
tothedefaultvalueof300seconds:
Matrix(rw)->set multiauth idle-timeout
show multiauth session-timeout
Usethiscommandtodisplaysessiontimeoutvalues,inseconds,forallauthenticationmethods.
Syntax
show multiauth session-timeout
Parameters
None
Defaults
None.
Mode
Switchcommand,ReadOnly.
Example
Thisexampleshowshowtodisplaymultipleau thenticationsessiontimeoutvalues,foranactive
session:
Matrix(rw)->show multiauth session-timeout
Authentication type Timeout (sec)
------------------- -------------
dot1x 0
pwa 0
mac 0
cep 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals