clear rmon alarm Configuring RMON
Enterasys Matrix DFE-Gold Series Configuration Guide 11-23
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Usage
AnRMONalarmentrycanbecreatedusingthiscommand,configuredusingthesetrmonalarm
propertiescommand(“setrmonalarmpropertiesonpage 1121),thenenabledusingthis
command.AnRMONalarmentrycanbecreatedandconfiguredatthesametimebyspecifying
anunusedindexwiththe
setpropertiescommand.
Analarmisanotificationthatastatisticalsampleofamonitoredvariablehascrossedaconfigured
threshold.
Example
ThisexampleshowshowtoenableRMONalarmentry3:
Matrix(rw)->set rmon alarm status 3 enable
clear rmon alarm
UsethiscommandtodeleteanRMONalarmentry.
Syntax
clear rmon alarm index
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtoclearRMONalarm entry1:
Matrix(rw)->clear rmon alarm 1
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
enable Enablesthisalarmentry.
index Specifiestheindexnumberofentrytobecleared.