Configuring Spanning Tree Loop Protect Features set spantree lptrapenable
6-74 Spanning Tree Configuration
Example
ThisexampleshowshowtoresettheLoopProtecteventwindowtothedefaultof180seconds:
Matrix(rw)->clear spantree lpwindow
set spantree lptrapenable
UsethiscommandtoenableordisableLoopProtecteventnotification.
Syntax
set spantree lptrapenable {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Usage
LoopProtecttrapsaresentwhenaLoopProtecteventoccurs,thatis,whenaportgoestolistening
duetonotreceivingBPDUs.Thetrapindicatesport,SIDandloopprotectionstatus.
Example
ThisexampleshowshowtoenablesendingofLoopProtecttraps:
Matrix(rw)->set spantree lptrapenable enable
show spantree lptrapenable
UsethiscommandtodisplaythecurrentstatusofLoopProtecteventnotification.
Syntax
show spantree lptrapenable
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadOnly.
enable|disable EnablesordisablesthesendingofLoopProtecttraps.Defaultis
disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals