Configuring Simple Network Time Protocol (SNTP) clear sntp broadcast delay
13-6 SNTP Configuration
Example
ThisexampleshowshowtosettheSNTPbroadcastdelayto12000microseconds:
Matrix(rw)->set sntp broadcastdelay 12000
clear sntp broadcast delay
UsethiscommandtocleartheroundtripdelaytimeforSNTPbroadcastframes.
Syntax
clear sntp broadcastdelay
Parameters
None.
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtocleartheSNTPbroadcastdelaytime:
Matrix(rw)->clear sntp broadcastdelay
set sntp poll-interval
UsethiscommandtosetthepollintervalbetweenSNTPunicastrequests.
Syntax
set sntp poll-interval interval
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtosettheSNTPpollintervalto30seconds:
Matrix(rw)->set sntp poll-interval 30
interval Specifiesthepollintervalinseconds.Validvaluesare16to16284.