clear rmon channel Configuring RMON
Enterasys Matrix DFE-Gold Series Configuration Guide 11-37
Defaults
•Ifanactionisnotspecified,packetswillbeacceptedonfiltermatches.
•Ifnotspecified,controlwillbesettooff.
•Ifoneventandoffeventarenotspecified,nonewillbeapplied.
•Ifeventstatusisnotspecified,readywillbeapplied.
•Ifadescriptionisnotspecified,nonewillbe
applied.
•Ifownerisnotspecified,itwillbesettomonitor.
Mode
Switchcommand,ReadWrite.
Example
Thisexampleshowshowtoacceptfail edcontrolondescription“captureall”createanRMON
channelentry:
Matrix(rw)->set rmon channel 54313 fe.2.12
clear rmon channel
UsethiscommandtoclearanRMONchannelentry.
Syntax
clear rmon channel index
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtoclearRMONchannelentry2:
Matrix(rw)->clear rmon channel 2
show rmon filter
UsethiscommandtodisplayoneormoreRMONfilterentries.
Syntax
show rmon filter [index index | channel channel]
index Specifiesthechannelentrytobecleared.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals