set inlinepower threshold Configuring Power over Ethernet (PoE)
Enterasys Matrix DFE-Gold Series Configuration Guide 2-67
Example
Thisexampleshowshowtoclearpowerassignmentstoallmodulesinthechassis:
Matrix(rw)->clear inlinepower assigned
set inlinepower threshold
UsethiscommandtosetthePoEusagethresholdonaspecifiedmodule.
Syntax
set inlinepower threshold usage-threshold module-number
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
Example
ThisexampleshowshowtosetthePoEthresholdto50onmodule1:
Matrix(rw)->set inlinepower threshold 50 1
clear inlinepower threshold
UsethiscommandtoresetthePoEusagethresholdonaspecifiedmoduletothedefaultvalueof
75percent.
Syntax
clear inlinepower threshold module-number
Parameters
Defaults
None.
Mode
Switchcommand,ReadWrite.
usagethreshold SpecifiesaPoEthresholdasapercentageoftotalsystempowerusage.
Validvaluesare1‐99.
modulenumber SpecifiesthemoduleonwhichtosetthePoEthreshold.
modulenumber SpecifiesthemoduleonwhichtoresetthePoEthreshold.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Enterasys Matrix DFE-Gold Series and is the answer not in the manual?

Enterasys Matrix DFE-Gold Series Specifications

General IconGeneral
BrandEnterasys
ModelMatrix DFE-Gold Series
CategorySwitch
LanguageEnglish

Related product manuals