Analog-to-Digital Converter (ADC)
MPC5606S Microcontroller Reference Manual, Rev. 7
146 Freescale Semiconductor
Address:
Base + 0x0004 Access: User read-only
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
R
0 0 0 0 0 0 0
N START
J ABORT
0 0
J START
0 0 0 0
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
R CHADDR[0:6] 0 0 0
ACK0
0 0 ADCSTATUS[0:2]
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
Figure 5-6. Main Status Register (MSR)
Table 5-8. MSR field descriptions
Field Description
0–6 Reserved
A write of any value has no effect. The read value is always 0.
7
NSTART
This status bit signals that a normal conversion is ongoing. This bit stays high while the
conversion is ongoing (or pending during injection mode).
8
JABORT
This status bit signals that an injected conversion has been aborted. This bit is reset when a
new injected conversion starts.
9–10 Reserved
A write of any value has no effect. The read value is always 0.
11
JSTART
This status bit signals that an injected conversion is ongoing.
12–14 Reserved
A write of any value has no effect. The read value is always 0.
15 Reserved
A write of any value has no effect. The read value is always 0.
16–22
CHADDR[0:6]
Channel under measure address
This status bit signals which channel is under measure.
23–25 Reserved
A write of any value has no effect. The read value is always 0.
26
ACKO
Auto-clock-off enable
This status bit signals if the Auto-clock-off feature is on.
27–28 Reserved
A write of any value has no effect. The read value is always 0.