Stepper Motor Controller (SMC)
MPC5606S Microcontroller Reference Manual, Rev. 7
Freescale Semiconductor 1135
 
35.3.2.14 Short-circuit Detector Interrupt Register 1 (MCSDI1)
35.3.2.15 Short-circuit Detector Interrupt Register 2 (MCSDI2)
35.4 Functional description
35.4.1 Modes of operation
35.4.1.1 PWM output modes
The SMC is configured between three output modes. 
Offset Module Base + 0x004D
0 1 2 3 4 5 6 7
R SDIF
W rwm rwm rwm rwm rwm rwm rwm rwm
Reset 0 0 0 0 0 0 0 0
Figure 35-15. Short-circuit Detector Interrupt Register 1 (MCSDI1)
Table 35-17. MCSDI1 field descriptions
Field Description
SDIF Short-circuit Detector Interrupt Flag — In case of a detected short-circuit, the corresponding bit 
according to the mapping in Table  35-23 is set in the short-circuit detector interrupt register.
If this specific interrupt is also enabled in the interrupt enable register MCSDIEN1, than this event will 
rise an external interrupt.
Offset Module Base + 0x004E
0 1 2 3 4 5 6 7
R SDIF
W rwm rwm rwm rwm rwm rwm rwm rwm
Reset 0 0 0 0 0 0 0 0
Figure 35-16. Short-circuit Detector Interrupt Register 2 (MCSDI2)
Table 35-18. MCSDI2 field descriptions
Field Descriptions
SDIF Short-circuit Detector Interrupt Flag — In case of a detected short-circuit, the corresponding bit 
according to the mapping in Table  35-23 is set in the short-circuit detector interrupt register.
If this specific interrupt is also enabled in the interrupt enable register MCSDIEN2, than this event will 
rise an external interrupt.