LCD Driver (LCD64F6B)
MPC5606S Microcontroller Reference Manual, Rev. 7
788 Freescale Semiconductor
Selectable continuous drive of LCD while in power down mode
22.2.3 Modes of operation
The LCD64F6B module supports up to seven operation modes with different numbers of backplanes and
different biasing levels.During power saving mode the LCD operation can be suspended under software
control. Depending on the state of internal bits, the LCD can operate normally with source clock applied,
or the LCD clock generation can be turned off and the LCD64F6B module enters a power conservation
state.
This is a high-level description only, detailed descriptions of operating modes are contained in later
sections.
22.3 External signal description
22.3.1 Detailed signal descriptions
Table 22-3. Signal properties
Name Port Function Reset
Pullu
p
m
Backplane
Waveforms
BP[m1:0
]
Backplane waveform signals that connect directly to the pads high impedance
n Frontplane
Waveforms
FP[n1:0] Frontplane waveform signals that connect directly to the pads high impedance
LCD Voltage VLCD LCD reference supply voltage
VDDX
Voltage
VDDX LCD supply voltage
VSSX
Voltage
VSSX LCD ground voltage
Table 22-4. Interface A—detailed signal descriptions
Signal Description
BP[m1:0] This output signal vector represents the analog backplane waveforms of the LCD64F6B module and
is connected directly to the corresponding pads.
FP[n1:0] This output signal vector represents the analog frontplane waveforms of the LCD64F6B module and
is connected directly to the corresponding pads.
VLCD Positive reference supply voltage for the LCD waveform generation.
VDDX Positive supply voltage for the LCD waveform generation.
VSSX Ground supply voltage for the LCD waveform generation.