Nexus Development Interface (NDI)
MPC5606S Microcontroller Reference Manual, Rev. 7
968 Freescale Semiconductor
26.6.2.8 Watchpoint Trigger Register (WT)
The watchpoint trigger register allows the watchpoints defined within the Nexus1 logic to trigger actions.
These watchpoints can control program and/or data trace enable and disable. The WT bits can be used to
produce an address-related window for triggering trace messages.
Table 26-10 details the watchpoint trigger register fields.
Nexus
Reg:
0x000A Access: User read/write
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
R
RWD[0-15]
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
R
RWD[16-31]
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Figure 26-10. Read/Write Access Data Register (RWD)
Nexus
Reg:
0x000B Access: User read/write
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
R
PTS PTE
0 0 0 0 0 0 0 0 0 0
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
R 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
W
Reset 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Figure 26-11. Watchpoint Trigger Register (WT)