EC Circle SearchFH/FZ5 Processing Item Function Reference Manual
155
2
Inspecting and Measuring
*1: The reference coordinates based on the selection in the Method area of the [Ref.setting] tab can be Get only.
*2: The reference coordinates based on the selection of Numerical in the Method area of the [Ref.setting] tab can be Set/Get.
161 Upper limit of count Set/Get 0 to 256
162 Lower limit of count Set/Get 0 to 256
165 Upper limit of radius Set/Get 0 to 99999.9999
166 Lower limit of radius Set/Get 0 to 99999.9999
171 Search type Set/Get
0: Single search
1: Multi search
172 Candidate point level Set/Get 0 to 100
173 Sort type Set/Get
0: X ascending
1: X descending
2: Y ascending
3: Y descending
4: Eva. ascending
5: Eva. descending
6: Radius ascending
7: Radius descending
176 Grouping distance Set/Get 1 to 10
177 Radius range Set/Get 1 to 9999
178 Radius Set/Get 1 to 9999
180
Sticking out circle isn't
detected
Set/Get
0: OFF
1: ON
181
Setting unit of reference
coordi
nate
Set/Get -1 to 9999
182
Reference type of
refe
rence coordinate
Set/Get
0: Numerical
1: Unit reference
183
Use point coordinate
before scroll
Set/Get
0: Not used
1: Used
184 Position X before scroll Set/Get -99999.9999 to 99999.9999
185 Position Y before scroll Set/Get -99999.9999 to 99999.9999
1000 + N × 4
(N = 0 to 255)
Position X Get only -99999.9999 to 99999.9999
1001 + N × 4
(N = 0 to 255)
Position Y Get only -99999.9999 to 99999.9999
1002 + N × 4
(N = 0 to 255)
Evaluation Get only 0 to 100
1003 + N × 4
(N = 0 to 255)
Radius Get only 0 to 99999.9999
6002 Format Set/Get
1: monochrome camera
0: color camera
No. Data name Set/Get Data range