Camera CalibrationFH/FZ5 Processing Item Function Reference Manual
817
4
Support Inspection and Measurement
3 Click [Generate calibration parameters].
The calibration parameters will be generated.
Sampling (Camera Calibration)
Make the calibration setting based on the measurement results. After measuring a position using the
measurement processing items in the measurement flow, set the position as an actual coordinates to calculate
calibration data.
1 In the Item Tab area, click [Sampling].
2 Set the [Sampling] area.
3 Click [Model] and [Region] as needed to set sampling measurement conditions.
4 Click [Sampling measurement].
Setting item
Setting value
[Factory default]
Description
XY specification
method
• [Different]
•Same
Different: Set X and Y individually.
Same: Use the measurement results of the Processing Unit
selected fo
r X specification to specify Y.
X specification
• Processing Unit that can
measure positions during
the measurement flow.
• [None]
Select the Processing Unit in the measurement flow used to
sample the
X coor
dinate.
Y specification
• Processing Unit that can
measur
e positions during
the measurement flow.
• [None]
Select the Processing Unit in the measurement flow used to
sample the
Y coordinate.
If "Same" is specified as the XY specification method, this cannot
be
se
lected.