Circular Scan Edge WidthFH/FZ5 Processing Item Function Reference Manual
283
2
Inspecting and Measuring
Item List for Circular Scan Edge Width
Region Setting (Circular Scan Edge Width)
This item is used to set up the measurement area.
Specify the measurement region of [Circular Scan Edge
Width] by using circular shapes.
1 In the Item Tab area, click [Region setting].
2 Use the Drawing tools to specify the measurement region.
To align with the measurement area and specify
the measurement point again, uncheck "Fix
region count".
3 Click [OK] in the Figure setting area.
• [OK]: Changes the settings and returns to the previous menu.
• [Cancel]: Changes are discarded. R
eturns to the previous menu.
• [Apply]: Updates the settings without leaving edit window.
4 In the "Region" area, specify a value for
each item.
Item name Description
Region setting
This item is used to set up the measurement area.
Reference: Region Setting (Circular Scan Edge Width) (p.283)
Edge color
(for color cameras only)
This item selects the color informa
t
ion for the edges to be detected.
Reference: Edge Color Specification - For Color Cameras Only (Circular Scan Edge Width)
(p.285)
Measurement
This item changes the measurement parameter as n
e
cessary when the measurement result is
unstable.
The displayed items depend on whether your camera
is
a color or monochrome camera. Normally,
the factory default value will be used.
Reference: Measurement Parameters (Circular Scan Edge Width) (p.286)
Judgement
This item specifies the judgement co
ndition for measurement results.
Reference: Judgement Conditions (Circular Scan Edge Width) (p.288)
Output parameter
This item can be changed if necessary. Normally, the factory default value may be used.
Select the measurement result coordinates and set how to handle the coordinates.
Reference: Output Parameters (Circular Scan Edge Width) (p.289)
Setting item
Set value
[Factory default]
Description
Width measure type
• [Circumference]
• Diameter
Select the measurement target for the workpi
ece.
Direction
•In→Out
•[Out→In]
Set the
measurement direction wh
en [Diameter] is
selected.