Measurement Image Switching
86
FH/FZ5 Processing Item Function Reference Manual
External Reference Tables (Measurement Image Switching)
No. Data name Set/Get Data range
0 Judge Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
-10: Error (image format mismatch)
-11: Error (unregistered model)
-12: Error (Insufficient memory)
-20: Error (Other error)
120 Target unit Set/Get
Unit that outputs images subject to reset
0 to 9999
121 Image no. Set/Get
Target image No, that the target unit holds
Image no. 0 to 9,999