EasyManua.ls Logo

Omron fh-3 series - External Reference Tables (Fine Matching)

Omron fh-3 series
904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fine MatchingFH/FZ5 Processing Item Function Reference Manual
389
2
Inspecting and Measuring
External Reference Tables (Fine Matching)
No. Data name Set/Get Data range
0 Judgement result Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
5 Number of labeling Get only 0 to 9999
6 Area Get only 0 to 999999999.9999
7 Position X Get only -99999.9999 to 99999.9999
8 Position Y Get only -99999.9999 to 99999.9999
101 Output coordinates Set/Get
0: After scroll
1: Before scroll
102 Calibration Set/Get
0: OFF
1: ON
103
Reflect to overall
j
udg
ement
Set/Get
0: ON
1: OFF
120 Boundary inspection Set/Get
0: OFF
1: ON
121 Boundary level Set/Get 0 to 9
122 Normalization Set/Get
0: OFF
1: ON
123 Perturbation processing Set/Get
0: OFF
1: ON
124 Difference Set/Get 0 to 255
125 Inspection Set/Get
0: Binary
1: Labeling
126 Label No. Set/Get 0 to 2499
127 Sort condition Set/Get
0: Area ascending
1: Area descending
2: X ascending
3: X descending
4: Y ascending
5: Y descending
128
Upper limit of label area
co
nditio
n
Set/Get 0 to 999999999.9999
129
Lower limit of label area
co
nditio
n
Set/Get 0 to 999999999.9999
130
Upper limit of quantity
j
udg
ement
Set/Get 0 to 9999
131
Lower limit of quantity
j
udg
ement
Set/Get 0 to 9999
132
Upper limit of area
j
udgement
Set/Get 0 to 999999999.9999
133
Lower limit of area
j
udg
ement
Set/Get 0 to 999999999.9999
134 Upper limit of position X Set/Get -99999.9999 to 99999.9999
135 Lower limit of position X Set/Get -99999.9999 to 99999.9999
136 Upper limit of position Y Set/Get -99999.9999 to 99999.9999
137 Lower limit of position Y Set/Get -99999.9999 to 99999.9999

Table of Contents