ClassificationFH/FZ5 Processing Item Function Reference Manual
215
2
Inspecting and Measuring
Settings Flow (Classification)
Classification can be set up as follows.
List of Classification Items
Model Registration (Classification)
Pre-register as models the sections to be used as reference for classification.
Models can be registered with any of 200 indexes, from 0
to 199, and up to 5 models can be registered for each
index.
When there is variation among the model print quality and sh
ape
s, pre-register multiple models for the same
index.
1 In the Item Tab area, click [Model].
2 In the "Setting model" area, select a
model and click [New].
3 Use the Drawing tools to specify the model registration range.
Item name Description
Model
This item registers the pattern characteristic of the measu
rement image as a model.
Model parameter values can be changed as needed to address unstable measurement results or to
increase the
processing speed. Normally, the factory default value will be used.
Reference: Model Registration (Classification) (p.215)
Region setting
This item is used to set up the measurement area.
Instead of measuring the entire input image, narrowing
the measurement area shortens the processing
time.
Reference: Region Setting (Classification) (p.218)
Measurement
This item specifies the judgement condition for measurem
ent results. Specify the criteria to judge the
measurement result if the X and Y coordinates and the correlation values with the model are OK.
Reference: Measurement Parameters (Cla
ssi
fication) (p.219)
Output
parameter
This item can be changed if necessary. Normally, the factory default value will be used.
Use the output parameter to specify how to handle the coordinates.
Reference: Output Parameters (Classification) (p.220)
Necessary Steps Optional Steps
Verify/Adjust results
▲
Model Registration (Classification)
▲
Region Setting (Classification)
▲
Measurement Parameters (Classification)
Start
Settings completed
Test measurement
▲
Output Parameters (Classification)