Camera SwitchingFH/FZ5 Processing Item Function Reference Manual
83
1
Input image
Camera Switching
Used in the Following Case
When switching to images on cameras other than that has been set to [Camera Image Input]
during scene processing
Camera Selection (Camera Switching)
1 Select the cameras used for
measurement.
2 Click [OK].
The settings are finalized.
Additional Explanation (Camera Switching)
When creating a scene, [Position Compensation] will be disabled if [Camera Switching] is positioned after a
[Position Compensation] unit, and this will restore the image of the measurement object to its former state before
the position compensation was applied.
When switching from a monochrome camera to color camera, reconfigure the settings in the following units.
Camera switching cannot be used with camera image input HDR.
Camera
0
Camera
1
Camera
2
Camera
3
Select a
camera
Important
The Position Compensation for Unit 1 is being
cancelled, making it restore to its former state before
the Position Compensation was applied.