Inspecting and Measuring
Measurement Parameters (Ec Cross)
Set the sort conditions/judgement conditions of crosshairs.
1 In the Item Tab area, click [Measurement].
2 In the "Sort cond." area, set the sorting
conditions.
3 When the setting has been changed,
click [Measure] to verify whether
measurements can be made correctly.
4 Set up the judgement condition.
Output Parameters (Ec Cross)
Set how to treat the coordinates to be output to the external device as measurement results. This item can be
changed if necessary.
1 Click [Output parameter] in the Item Tab area.
2 Specify each of the following items.
Setting item
Setting value
[Factory default]
Description
Order
• [Cross X]
• Cross Y
• Length
Select the sorting method to be applied to those measurement results
w
h
ere there are multiple intersections.
• [Ascending]
• Descending
Cross No. [0] to 9 Set the cross number for the data to be output.
Setting item
Setting value
[Factory default]
Description
Cross X [-99999.9999] to [99999.9999] Set the range of X coordinates of crosshair that is judged to be OK.
Cross Y [-99999.9999] to [99999.9999] Set the range of Y coordinates of crosshair that is judged to be OK.
Angle [-45] to [45] Set the crosshair angles that are judged to be OK.
Count [1] to [10] Set the number of detections of crosshair that is judged to be OK.
Setting item
Setting value
[Factory default]
Description
Output coordinates
• [After scroll]
• Before scroll
As measurement results, select whether
to output coordinate values to
external devices before or after the position compensation is applied.
Calibration
•[OFF]
•ON
Select whether to reflect the calibration in the values output to the
external
device as measurement results.
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
Reflect to overall
ju
dgemen
t
•[ON]
•OFF
Specify whether or not the judgement results of this processing unit is
reflected in the scene overall judgement.