EasyManua.ls Logo

Omron fh-3 series - External Reference Tables (Edge Position)

Omron fh-3 series
904 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edge PositionFH/FZ5 Processing Item Function Reference Manual
233
2
Inspecting and Measuring
External Reference Tables (Edge Position)
No. Data name Set/Get Data range
0 Judge Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
-10: Error (image format mismatch)
-11: Error (unregistered model)
-12: Error (Insufficient memory)
-20: Error (Other error)
5 Edge position X Get only 0 to 99999.9999
6 Edge position Y Get only 0 to 99999.9999
7 Reference X
*1
Get only 0 to 99999.9999
8 Reference Y
*1
Get only 0 to 99999.9999
101 Output Coordinates Set/Get
0: After scroll
1: Before scroll
102 Calibration Set/Get 0: OFF, 1: ON
103
Reflect to overall
j
udgement
Set/Get 0: ON, 1: OFF
120 Edge color specification Set/Get
0: OFF
1: ON
121 Edge color R Set/Get 0 to 255
122 Edge color G Set/Get 0 to 255
123 Edge color B Set/Get 0 to 255
124 Difference R Set/Get 0 to 127
125 Difference G Set/Get 0 to 127
126 Difference B Set/Get 0 to 127
127 Edge detection mode Set/Get
0: Color IN
1: Color OUT
129 Reference X
*2
Set/Get 0 to 99999.9999
130 Reference Y
*2
Set/Get 0 to 99999.9999
131 Edge No. Set/Get 0 to 99
132 Edge Level Set/Get 0 to 100
133 Noise level Set/Get
Color camera: 0 to 442
Monochrome camera: 0 to 255
134 Noise width Set/Get 0 to 9999
135 Edge color level Set/Get 0 to 442
136
Upper limit of the edge
position X
Set/Get -99999.9999 to 99999.9999
137
Lower limit of the edge
position X
Set/Get -99999.9999 to 99999.9999
138
Upper limit of the edge
position Y
Set/Get -99999.9999 to 99999.9999
139
Lower limit of the edge
position Y
Set/Get -99999.9999 to 99999.9999
140
Monochrome edge
d
etection mode
Set/Get
0: LightDark
1: DarkLi
ght

Table of Contents