Edge PositionFH/FZ5 Processing Item Function Reference Manual
233
2
Inspecting and Measuring
External Reference Tables (Edge Position)
No. Data name Set/Get Data range
0 Judge Get only
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
-10: Error (image format mismatch)
-11: Error (unregistered model)
-12: Error (Insufficient memory)
-20: Error (Other error)
5 Edge position X Get only 0 to 99999.9999
6 Edge position Y Get only 0 to 99999.9999
7 Reference X
*1
Get only 0 to 99999.9999
8 Reference Y
*1
Get only 0 to 99999.9999
101 Output Coordinates Set/Get
0: After scroll
1: Before scroll
102 Calibration Set/Get 0: OFF, 1: ON
103
Reflect to overall
j
udgement
Set/Get 0: ON, 1: OFF
120 Edge color specification Set/Get
0: OFF
1: ON
121 Edge color R Set/Get 0 to 255
122 Edge color G Set/Get 0 to 255
123 Edge color B Set/Get 0 to 255
124 Difference R Set/Get 0 to 127
125 Difference G Set/Get 0 to 127
126 Difference B Set/Get 0 to 127
127 Edge detection mode Set/Get
0: Color IN
1: Color OUT
129 Reference X
*2
Set/Get 0 to 99999.9999
130 Reference Y
*2
Set/Get 0 to 99999.9999
131 Edge No. Set/Get 0 to 99
132 Edge Level Set/Get 0 to 100
133 Noise level Set/Get
Color camera: 0 to 442
Monochrome camera: 0 to 255
134 Noise width Set/Get 0 to 9999
135 Edge color level Set/Get 0 to 442
136
Upper limit of the edge
position X
Set/Get -99999.9999 to 99999.9999
137
Lower limit of the edge
position X
Set/Get -99999.9999 to 99999.9999
138
Upper limit of the edge
position Y
Set/Get -99999.9999 to 99999.9999
139
Lower limit of the edge
position Y
Set/Get -99999.9999 to 99999.9999
140
Monochrome edge
d
etection mode
Set/Get
0: Light→Dark
1: Dark→Li
ght