Date Verification
404
FH/FZ5 Processing Item Function Reference Manual
Date Parameters (Date Verification)
This item sets the date/time format and update conditions.
1 In the Item Tab area, click [Date parameter].
2 When comparing with character strings
with an expiration date limit, set each
item in the "Period setting" area.
3 In the "Date setting" area, specify a
value for each item.
Setting item
Set value
[Factory default]
Description
Yea r
0 to 99
[0]
This item sets the usage perio
d from the current date.Month
0 to 99
[0]
Day
-999 to 999
[0]
Setting item
Set value
[Factory default]
Description
Auto Update
• Not update
• First measure
• [Always update]
Set the year, month and day updating conditions. The clock time is always
updated.
•
Not update: The date is stored
in
to memory when the processing unit is
registered. The date is not updated until the next time date update is
executed with the menu.
• First measure: The date is updated du
ring the first measurement after
start up.
• Always update: The date is updated every measurement.
Zero suppress
•[0]
•Space
Set how the tens digits of the month and day are displayed.
Calculation order
• [Month→Day]
•Day→Month
Set whether to calculate the month first or the
day first when the usage
period is set. (This affects calculation of end of month.)
Month end adjust
• [Last day of
current month]
• First day of next
month
• Gap day of next
month
Set the adjustment method that will be used
if the result of the expiration