EasyManua.ls Logo

Omron fh-3 series - Elapsed Time

Omron fh-3 series
904 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Elapsed TimeFH/FZ5 Processing Item Function Reference Manual
689
4
Support Inspection and Measurement
Elapsed Time
Calculate the elapsed time in milliseconds after the measurement starts.
You can add this processing item to a scene and setup is not required.
Used in the Following Case
When combining with the conditional branch for stopping measurement after the specified
processing time has elapsed.
When calculating the processing execution time of a unit
Branch condition
Elapsed time ≤ 100 → Unit 4
Elapsed time > 100 → Unit 7
Scroll
Elapsed time
Conditional Branch
Search
1.
2.
3.
4.
Parallel Judge
5.
End
6.
End
7.
By setting up the arithmetic expression for
“3. Elapsed time”-“1. Elapsed time”,
the measuring time of Unit 2 to 3 can then
be calculated.
Search
Elapsed time
Elapsed time
Calculation
1.
Set up the elapsed time before and after the unit respectively and specify
the arithmetic expression required for calculating their
2.
3.
4.