OCRFH/FZ5 Processing Item Function Reference Manual
469
2
Inspecting and Measuring
3 Click [Measure].
Measurement is executed and the results appear on the image.
4 Click the characters on the image.
You can set “Regist or not” and “Character” for the clicked characters.
5 Click [Character Regist].
The characters set with “regist” in “Regist or not” and the character codes set with “Code” are registered in
the OCR user dictionary processing unit set in “Dictionary unit” on the “Dictionary Setting” item tab, and
the number of characters that were registered appears.
Date Parameters (OCR)
Set the date and time format and update conditions.
1 Click [Date parameter] in the Item Tab area.
Setting item
Setting value
[Factory default]
Description
The initial state of
cod
e is register
• [Checked]
• Unchecked
To register all successfully measured characters in the dictionary
af
ter
confirmation measurement, select the “The initial state of
code is register” checkbox. The registration state of each
character after confirmation measurement will be “register”.
Setting item
Setting value
[Factory default]
Description
Regist or not
• unregist
• [register]
To register the characters in the dictionary, select “register”.
Character 0 to 9, A to Z, :/() Set the character code of the character you want to register.
• If the settings are not configured on the “Dictionary Settin
g” ite
m tab, [OCR User Dictionary] cannot be clicked.
Always configure the dictionary settings before registering characters in the dictionary.