EasyManua.ls Logo

Omron fh-3 series - Page 244

Omron fh-3 series
904 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Edge Pitch
242
FH/FZ5 Processing Item Function Reference Manual
120 Edge color R Set/Get 0 to 255
121 Edge color G Set/Get 0 to 255
122 Edge color B Set/Get 0 to 255
123 Edge color difference R Set/Get 0 to 127
124 Edge color difference G Set/Get 0 to 127
125 Edge color difference B Set/Get 0 to 127
127 Edge Level Set/Get 0 to 100
128 Noise Level Set/Get 0 to 442
129 Noise width Set/Get 0 to 9999
130 Upper limit of edge pitch Set/Get 0 to 1000
131 Lower limit of edge pitch Set/Get 0 to 1000
132 Upper limit of average pitch Set/Get 0 to 99999.9999
133 Lower limit of average pitch Set/Get 0 to 99999.9999
134 Upper limit of the pitch Set/Get 0 to 99999.9999
135 Lower limit of the pitch Set/Get 0 to 99999.9999
136
Upper limit of average
wi
d
th
Set/Get 0 to 99999.9999
137
Lower limit of Average
wi
d
th
Set/Get 0 to 99999.9999
138 Upper limit of the width Set/Get 0 to 99999.9999
139 Lower limit of the width Set/Get 0 to 99999.9999
140 Edge color level Set/Get 0 to 442
141 Color to count Set/Get
0: White
1: Black
142 Mode Set/Get
0: Normal
1: Precise
No. Data name Set/Get Data range

Table of Contents

Related product manuals