Scan Edge WidthFH/FZ5 Processing Item Function Reference Manual
267
2
Inspecting and Measuring
*1: On the [Measurement] tab of the Properties Dialog Box, this data is displayed as [Edge Upper] when you choose the [Position
(%) for width of a color].
*2: On the [Measurement] tab of the Properties Dialog Box, this data is displayed as [Edge Upper] when you choose the [Value
(442
at the maximum) of color].
141
Monochrome edge detection
mode
Set/Get
0: Light→dark
1: Dark→l
ight
142
Ed
ge level lower limit absolute
value
Set/Get
Color camera:0 to 442
Monochrome camera: 0 to 255
143
Edge level specification
method
Set/Get
0: %
1: Absolute value
145 Measurement point Set/Get 1 to 100
146 Mask size Set/Get 0 to 200
147 Display area Set/Get 1 to 99
148 Display area (direction) Set/Get
0: Forward
1: Reverse
149 Measure type Set/Get
0: Projection
1: Derivation
150 Fix region count Set/Get
0: Not fixed
1: Fixed
151
Monochrome Derivation edge
d
e
tection mode
Set/Get
0: Absolute
1: Dark→L
ight
2: L
ight→Dark
152 Edge level upper limit
*1
Set/Get 0 to 100
153
Edge level upper limit absolute
va
lue
*2
Set/Get
Color camera:0 to 442
Monochrome camera: 0 to 255
154 Filter Strength Set/Get 0 to 100
6002 Format Set/Get
1: monochrome camera
2: color camera
No. Data name Set/Get Data range