Fine Matching
386
FH/FZ5 Processing Item Function Reference Manual
3 When the setting has been changed,
click [Measurement] in the Detail area to
verify whether measurements can be
made correctly.
4 Set up the judgement condition.
Sort condition
Specify the conditions by which label number is re-assigned.
When sorting referencing the X and Y coordinates, the
upper left is the origin. This will not
affect the coordinate systems set up through the [Camera Image Input] calibration.
Area ascending
Number re-assigning begins from the labels with smaller areas.
[Area descending] Number re-assigning begins from labels with larger area.
X ascending
Number re-assigning begins from the label with a smaller gravity X
coordinate.
X descending
Number re-assigning begins from the label with a larger gravity X
coordi
nate.
Y ascending
Numbe
r re-assigning begins from the label with a smaller gravity Y
coordinate.
Y desce
nding
Number re-assigning begins from the label with a larger gravity Y
coordinate.
La
bel area [0] to [999999999] Specify the range of the area to be judged as a label.
Setting item Set value Description
Quantity 0 to 9999
Specify the range of the numb
er of labels that is judged to be
OK.
When "Binary area" is used, the w
h
ite pixels as a whole will be
regarded as one label.
Area 0 to 999999999.9999
Specify the range of the area
that is judged to be OK.
When the "Labeling" is used, the area of the label number will
be
specified instead.
Item
Set value
[Factory default]
Description