SearchFH/FZ5 Processing Item Function Reference Manual
109
2
Inspecting and Measuring
*1: The reference coordinates based on the selection in the Method area of the [Ref.setting] tab can be Get only.
*2: The reference coordinates based on the selection of Numerical in the Method area of the [Ref.setting] tab can be Set/Get.
1003 + NN × 4
(NN = 0 to 31)
Measure angle Get only -180 to 180
5100 Re-register Set only 1: Execute
30000 Correlation value Get only 0 to 100
40000 Edge position X Get only 0 to 99999.9999
50000 Edge position Y Get only 0 to 99999.9999
60000 Measure angle Get only
-180 to 180
No. Data name Set/Get Data range