Circular Scan Edge PositionFH/FZ5 Processing Item Function Reference Manual
281
2
Inspecting and Measuring
*1: The reference coordinates based on the selection in the Method area of the [Ref.setting] tab can be Get only.
*2: The reference coordinates based on the selection of Numerical in the Method area of the [Ref.setting] tab can be Set/Get.
*3: On the screen, this data is displayed as [Edge Upper] when you choose [Position (%) for width of a color] of [Measurement].
*4: On the screen, this data is displayed as [Edge Upper] when [Value of color difference(Max.244)] of [Measurement].
213
Monochrome edge
de
tection mode
Set/Get
0: Light→Dark
1: Dark→Li
ght
214
Ed
ge level Lower limit
absolute value
Set/Get
color camera: 0 to 442
monochrome camera: 0 to 255
215
Edge level specification
method
Set/Get
0: %
1: Absolute value
216 Measure type Set/Get
0: Projection
1: Derivation
217
Monochrome Derivation
e
dge
detection mode
Set/Get
0: Absolute
1: Dark→Li
ght
2
: Light→Dark
218 Edge Level Upper limit
*3
Set/Get 0 to 100
219
Edge level Upper limit
absolute value
*4
Set/Get
color camera: 0 to 442
monochrome camera: 0 to 255
220 Filter Strength Set/Get 0 to 100
221
Setting unit of reference
co
ordin
ate
Set/Get -1 to 9,999
222
Setting type of reference
co
ordinate
Set/Get
0: Numerical
1: Unit
223
Use point coordinate
be
fo
re scroll
Set/Get
0: Not use
1: Use
224 Position X before scroll Set/Get -99,999.9999 to 99,999.9999
225 Position Y before scroll Set/Get -99,999.9999 to 99,999.9999
6002 Format Set/Get
1: monochrome camera
2: color camera
No. Data name Set/Get Data range