588
FH/FZ5 Processing Item Function Reference Manual
Changing the Binary Filter Settings (Monochrome Images Only)
You can change the settings of the filter that binarizes images.
Setting item
Setting value
[Factory default]
Description
Binary level
0 to 255
[128] to [255]
Set the level for conversion of a
256 gradation grayscale image to a binary
image.
Set the “Binary level” so that the pixel
s
of the measurement target are white.
Reverse
•Checked
[Unchecked]
Select the “Reverse” checkbox to reverse black and white.