Siemens G130 - r9785[0...1] SI Motion diagnostics sensorless minimum current; Diag sl I_min; r9786[0...2] SI Motion diagnostics sensorless angle; Diag sl angle; r9787 SI Motion diagnostics sensorless velocity deviation; Diag sl v_dev

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
1000 List Manual (LH2), 07/2016, A5E03263479A
Description: Display to diagnose currents of the encoderless actual value sensing.
Index: [0] = Minimum current parameterized
[1] = Minimum current measured
Dependency: Refer to: p9588
Note: For index 0:
Displays the parameterized minimum current of p9588.
For index 1:
Displays the currently measured current of the encoderless actual value sensing
Description: Display to diagnose the angle for sensorless actual value sensing.
Index: [0] = Plausibility angle actual value
[1] = Voltage angle actual value
[2] = Current angle actual value
Dependency: Refer to: p9585
Note: For index 0:
Displays the actual plausibility angle.
For index 1:
Displays the actual voltage angle.
For index 2:
Displays the actual current angle.
Description: Displays the actual velocity deviation for sensorless actual value sensing.
This value is calculated when setting p9585/p9385.
The actual velocity has a deviation of +/- r9787 for 6 ms * p9585/p9385 within a monitoring time of 1 s.
Dependency: Refer to: p9585
Note: For linear axes, the following unit applies: millimeters per minute
For rotary axes, the following unit applies: revolutions per minute
r9785[0...1] SI Motion diagnostics sensorless minimum current / Diag sl I_min
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: 6_3 Unit selection: p0505
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mA] - [mA] - [mA]
r9786[0...2] SI Motion diagnostics sensorless angle / Diag sl angle
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [°] - [°] - [°]
r9787 SI Motion diagnostics sensorless velocity deviation / Diag sl v_dev
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [mm/min] - [mm/min] - [mm/min]