2 Parameters
2.2 List of parameters
SINAMICS G130/G150
772 List Manual (LH2), 07/2016, A5E03263479A
For bit 12:
Together with p7755, the bit is used to monitor write protection.
Bit = 1, if p7755 != 0 and write protection is active (p7760.0 = 1).
Bit = 0, if write protection was deactivated. p7755 is set to 0, and when write protection is activated again, bit 12
remains at 0.
Description: Setting for activating/deactivating the write protection for adjustable parameters.
Value: 0: Deactivate write protection
1: Activate write protection
Dependency: Refer to: r7760
Notice: While write protection is active, a download is prevented; however, it is still possible to restore the factory settings.
Note: Parameters with the "WRITE_NO_LOCK" attributes are excluded from the write protection.
A product-specific list of these parameters is also available in the corresponding List Manual.
Description: Sets the behavior for write protection when accessing via multi-master fieldbus systems (e.g. CAN, BACnet).
Value: 0: Write access independent of p7761
1: Write access dependent on p7761
Dependency: Refer to: r7760, p7761
Description: Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency: Refer to: p7764
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
p7761 Write protection / Write protection
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p7762 Write protection multi-master fieldbus system access behavior / Fieldbus acc_behav
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p7763 KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
All objects Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 500 1