2 Parameters
2.2 List of parameters
SINAMICS G130/G150
890 List Manual (LH2), 07/2016, A5E03263479A
Description: Setting to activate and configure the "Web server" function in the drive.
It is possible to access the web server via the integrated Ethernet and PROFINET interfaces of the drive. The
addressing is realized via the set IP address.
Description: This parameter allows the port setting for the web server to be changed.
Index: [0] = Port for standard transfer (http)
[1] = Port for secure transfer (https)
Description: Data setting to read topology properties.
The result is displayed depending on the property in r9207 or r9208.
For index 0:
0: actual topology, 1: target topology
For index 1:
Sets the component number of the component involved.
For index 2:
7: Name (r9208)
8: Component type (r9207)
9: Number of DRIVE-CLiQ connections (r9207)
11: Manufacturer (upper byte) and version (lower byte) (r9207)
12: Serial number (r9208)
13: Index (r9207)
15: Comparison level (r9207)
23: Article number (r9207)
24: Hardware serial number (r9208)
25: Envelope article number (r9207)
28: Firmware version (r9207)
p8986 Web server configuration / Web serv config
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0101 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Activating Yes No -
01 Only permit access via https Yes No -
02 Enable "SINAMICS" user Yes No -
03 Enable "Administrator" user Yes No -
p8987[0...1] Web server port assignment / WebServ PortAssign
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 32767 [0] 80
[1] 443
p9206[0...2] Topology direct access / Topo access
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 4294967295 0