EasyManua.ls Logo

Siemens G130 - Fig. 3-152 6792 - Interface to the Motor Module (RESM, p0300 = 6)

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1269
3 Function diagrams
3.16 Vector control
Fig. 3-152 6792 – Interface to the Motor Module (RESM, p0300 = 6)
- 2491 -
Function diagram
87654321
fp_6792_54_eng.vsd
DO: A_INF, B_INF, CU_G, CU_S, R_INF, S_INF, TM15DI_DO, TM31, TM120, TM150
S120/S150/G130/G150
27.06.13 V04.08.00
Vektorregelung  Schnittstelle zum Motor Module (RESM, p0300 = 6)
p0115[2] (Motor Modules)
- 6792 -
Function diagram
87654321
fp_6792_54_eng.vsd
DO: VECTOR
S120/S150/G130/G150
18.03.16 V04.08.00
Vector control - Interface to the Motor Module (RESM, p0300 = 6)
PWM
M
~
U
V
W
P24
M
2
U_setl
U_angle
[6640.1]
[6799.1]
[6714.8]
[6799.1]
[8021.1]
[6799.5]
[6791.1]
[6799.1]
[8021.1]
[6714.1]
p1764 p1767
[2526.2]
p1755 p1756
+
+
+
+
+
BRN
+
BRN
[6790.5]
[6030.8]
[6791.7]
[6790.4]
[2526.2]
+
+
[6714.8]
+
-
Pre-control speed
Current model Vibration damping
Outp_ph_seq rev
p1820 [D]
R_stator act [Ohm]
r0395 [M]
Flux model
Motor model
Model control
MotMod status
r1751
U_phase act val [V]
r0089[0...2]
r0069[0..8]
I_phase act val [A]
I_max PM
I_max PM
r1771
MotMod n_adapt Tn [rpm]
r1770
MotMod n_adapt
Kp [rpm]
Gain res_damp
p1740 [D]
r0066
f_outp [Hz]
ZSW cl-loop ctrl
r0056.11
r0056
r0074
Mod_depth [%]
r0072
U_output [Vrms]
Control Unit
Sign
+ or -
ZSW cl-loop ctrl
r0056.7
r0056
DC link voltage (Vdc)
Pulse enable HW
Motor Module
Brake control
r0070
Vdc act val [V]
r0094
Transformat_angle
DRIVE-CLiQ
RESM: Reluctance synchronous motor

Table of Contents

Related product manuals