2 Parameters
2.2 List of parameters
SINAMICS G130/G150
156 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the damping inductance of the separately excited synchronous motor in the rotor direction (d-axis).
Description: Displays the damping inductance of a separately excited synchronous motor quadrature to the rotor direction (q
axis).
Description: Displays the magnetizing inductance of the motor.
For separately excited synchronous motors:
Displays the saturated magnetizing inductance in the rotor direction (d-axis).
Note: The parameter is not used for synchronous motors (p0300 = 2xx).
Description: Displays the saturated magnetizing inductance of a separately excited synchronous motor quadrature to the rotor
direction (q axis).
r0380[0...n] Motor damping inductance d axis / Mot L_damp d
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: 15_1 Unit selection: p0349
Not for motor type: ASM, PMSM, REL,
RESM
Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0381[0...n] Motor damping inductance q axis / Mot L_damp q
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: 15_1 Unit selection: p0349
Not for motor type: ASM, PMSM, REL,
RESM
Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0382[0...n] Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: 15_1 Unit selection: p0349
Not for motor type: PMSM, REL, RESM Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]
r0383[0...n] Motor magnetizing inductance q axis saturated / Mot L_magn q sat
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: 15_1 Unit selection: p0349
Not for motor type: ASM, PMSM, REL,
RESM
Scaling: - Expert list: 1
Min Max Factory setting
- [mH] - [mH] - [mH]