SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
889
2 Parameters
2.2 List of parameters
Note: If value = 1:
A PROFIsafe connection is only accepted if an isochronous connection exists.
Relevant, if PROFIsafe and isochronous operation are configured via various communication connections (e.g.
PROFINET Shared Device).
Description: Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index: [0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency: Refer to: r8971, r8972
Note: Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
Description: Displays the IP address of the first PROFINET controller connected with the device via CBE20/CBE25.
Description: Displays the IP address of the second PROFINET controller connected with the device via CBE20/CBE25.
r8970[0...2] CBE2x subslot controller assignment / CBE2x subslot
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20), VECTOR_G
(PN CBE20), B_INF
(PN CBE20), TM31
(PN CBE20), TM120
(PN CBE20), TM150
(PN CBE20), TB30
(PN CBE20), ENC (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 8 -
r8971[0...3] CBE2x IP Address Remote Controller 1 / CBE2x IP Rem Ctrl1
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8972[0...3] CBE2x IP Address Remote Controller 2 / CBE2x IP Rem Ctrl2
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -