Fig. 3-54 2493 – IF2 send telegram, free interconnection
- 2493 -
Function diagram
87654321
fp_2493_54_eng.vsd
DO: A_INF, B_INF, CU_G, CU_S, R_INF, S_INF, TM15DI_DO, TM31, TM120, TM150
S120/S150/G130/G150
18.03.16 V04.08.00
PROFIdrive - IF2 send telegram, free interconnection
PROFIdrive sampling time
Reference quantities for further interconnection
p200x
<1> Not for G130/G150: TM15DI_DO, TM120.
Usable infeeds:
G130: none, G150: B_INF, S120: x_INF, S150: A_INF
<2> The number of PZD send words depends on the drive object type.
<3> The following representation applies for words: 4000 hex = 100 %. The reference variables p200x apply for the ongoing interconnection (100 % -> p200x).
For temperature values, the following applies: 100 °C -> 100 % = 4000 hex, 0 °C -> 0 %.
<4> Using the binector/connector converters at [2489], bits of 5 send words can be interconnected with any binectors.
PZD send word 1
PZD send word 2
PZD send word 3
PZD send word 4
PZD send word 5
<4>
(0)
p8851[1]
(0)
p8851[2]
(0)
p8851[3]
(0)
p8851[4]
(0)
p8851[0]
<3>
PZD send word 6
PZD send word 7
PZD send word 8
(0)
p8851[5]
(0)
p8851[6]
(0)
p8851[7]
IF2 Diag send word
r8853[0 25]
PZD send word 9(0)
p8851[8]
PZD send word 10
PZD send word 25(0)
p8851[24]
<1>
PROFIBUS
PROFINET
Drive object n
Header
Drive object 1
Drive object 2
.
.
.
.
.
.
Drive object m
Trailer
Send telegram
PZD send word 11
(0)
p8851[9]
(0)
p8851[10]
...
<2>