EasyManua.ls Logo

Siemens G130 - p9740 SI Motion user agreement selection;de-selection MM; SI mtn UserAgr MM; r9741 SI Motion user agreement inside the drive MM; SI Mtn UserAgr int; r9743.4...15 CO;BO: SI Safety Info Channel status word S_ZSW2 B; SIC S_ZSW2 B

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
988 List Manual (LH2), 07/2016, A5E03263479A
Note: SIC: Safety Info Channel
For bit 07:
An internal event is displayed if a STOP A ... F is active.
Description: Setting to select and de-select the user agreement on the Motor Module/Hydraulic Module.
Value: 0: [00 hex] De-select user agreement
172: [AC hex] Select user agreement
Dependency: Refer to: r9741
Description: Displays the internal state of the user agreement.
Value = 0: User agreement is not set.
Value = AC hex: User agreement is set.
Dependency: Refer to: p9740
Description: Display and BICO output for status word S_ZSW2B of the safety information channel.
04 SLS active Yes No -
05 SOS selected Yes No -
06 SLS selected Yes No -
07 Internal event Yes No -
09 Select SLS bit0 Yes No -
10 Select SLS bit1 Yes No -
12 SDI positive selected Yes No -
13 SDI neg selected Yes No -
14 ESR retract requested Yes No -
15 Safety message present Yes No -
p9740 SI Motion user agreement selection/de-selection MM / SI mtn UserAgr MM
VECTOR_G Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00AC hex 0000 hex
r9741 SI Motion user agreement inside the drive MM / SI Mtn UserAgr int
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: 2822
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r9743.4...15 CO/BO: SI Safety Info Channel status word S_ZSW2B / SIC S_ZSW2B
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Safety Integrated Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
04 SLP selected position area SLP2 SLP1 -
07 SLP selected and user agreement set Yes No -
08 SDI positive selected Yes No -
09 SDI neg selected Yes No -
12 Test stop active Yes No -
13 Test stop required Yes No -
14 Reference position required Yes No -
15 Reference trigger command identified or
reference position valid
Yes No -

Table of Contents