SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
887
2 Parameters
2.2 List of parameters
Description: Displays the actual standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the actual subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the actual DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Value: 0: DHCP off
2: DHCP on, identification using MAC address
3: DHCP on, identification via name of station
Notice: When the DHCP mode is active (parameter value greater than 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used by the STARTER/SCOUT commissioning tool.
Description: Displays the MAC address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the DAP ID for PROFINET via the Communication Board Ethernet 20/25 (CBE20/CBE25).
The combination of device ID (r8909) and DAP ID (r8959) uniquely identifies a PROFINET access point.
r8952[0...3] CBE2x Default Gateway actual / CBE2x def GW act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8953[0...3] CBE2x Subnet Mask actual / CBE2x Sub Mask act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8954 CBE2x DHCP Mode actual / CBE2x DHCP act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 -
r8955[0...5] CBE2x MAC address / CBE2x MAC Addr
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00FF hex -
r8959 CBE2x DAP ID / CBE2x DAP ID
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex -