Siemens G130 - r8952[0...3] CBE2 x Default Gateway actual; CBE2 x def GW act; r8953[0...3] CBE2 x Subnet Mask actual; CBE2 x Sub Mask act; r8954 CBE2 x DHCP Mode actual; CBE2 x DHCP act; r8955[0...5] CBE2 x MAC address; CBE2 x MAC Addr

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
887
2 Parameters
2.2 List of parameters
Description: Displays the actual standard gateway for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the actual subnet mask for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the actual DHCP mode for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Value: 0: DHCP off
2: DHCP on, identification using MAC address
3: DHCP on, identification via name of station
Notice: When the DHCP mode is active (parameter value greater than 0), PROFINET communication via this interface is no
longer possible! However, the interface can be used by the STARTER/SCOUT commissioning tool.
Description: Displays the MAC address for the Communication Board Ethernet 20/25 (CBE20/CBE25).
Description: Displays the DAP ID for PROFINET via the Communication Board Ethernet 20/25 (CBE20/CBE25).
The combination of device ID (r8909) and DAP ID (r8959) uniquely identifies a PROFINET access point.
r8952[0...3] CBE2x Default Gateway actual / CBE2x def GW act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8953[0...3] CBE2x Subnet Mask actual / CBE2x Sub Mask act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -
r8954 CBE2x DHCP Mode actual / CBE2x DHCP act
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 -
r8955[0...5] CBE2x MAC address / CBE2x MAC Addr
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex 00FF hex -
r8959 CBE2x DAP ID / CBE2x DAP ID
CU_G130_PN (PN
CBE20),
CU_G150_PN (PN
CBE20),
CU_G130_DP (PN
CBE20),
CU_G150_DP (PN
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex -