2 Parameters
2.2 List of parameters
SINAMICS G130/G150
642 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the status of the digital inputs of the Terminal Board 30 (TB30).
Dependency: Refer to: r4023
Note: DI: Digital Input
Description: Displays the inverted status of the digital inputs of Terminal Module 31 (TM31).
Dependency: Refer to: r4022
Note: DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
Description: Displays the inverted status of the digital inputs of the Terminal Board 30 (TB30).
r4022.0...3 CO/BO: TB30 digital inputs status / TB30 DI status
TB30 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9099, 9100
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X481.1) High Low -
01 DI 1 (X481.2) High Low -
02 DI 2 (X481.3) High Low -
03 DI 3 (X481.4) High Low -
r4023.0...11 CO/BO: TM31 digital inputs status inverted / TM31 DI status inv
TM31 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9549, 9550,
9552, 9560, 9562
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X520.1) High Low -
01 DI 1 (X520.2) High Low -
02 DI 2 (X520.3) High Low -
03 DI 3 (X520.4) High Low -
04 DI 4 (X530.1) High Low -
05 DI 5 (X530.2) High Low -
06 DI 6 (X530.3) High Low -
07 DI 7 (X530.4) High Low -
08 DI/DO 8 (X541.2) High Low -
09 DI/DO 9 (X541.3) High Low -
10 DI/DO 10 (X541.4) High Low -
11 DI/DO 11 (X541.5) High Low -
r4023.0...3 BO: TB30 digital inputs status inverted / TB30 DI status inv
TB30 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dyn. index: - Func. diagram: 9099, 9100
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 DI 0 (X481.1) High Low -
01 DI 1 (X481.2) High Low -
02 DI 2 (X481.3) High Low -
03 DI 3 (X481.4) High Low -