4 Faults and alarms
4.2 List of faults and alarms
SINAMICS G130/G150
1912 List Manual (LH2), 07/2016, A5E03263479A
F36214 (N, A) Hub: overvoltage fault 24 V supply
Message value: %1
Message class: Supply voltage fault (overvoltage) (3)
Drive object: B_INF, HUB, VECTOR_G
Component: Terminal Board (TB) Propagation: LOCAL
Reaction: NONE (OFF1, OFF2)
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The 24 V power supply on the DRIVE-CLiQ Hub Module has exceeded the fault threshold.
Fault value (r0949, interpret decimal):
Actual operating voltage in 0.1 °C resolution
Remedy: - check the supply voltage of the component involved.
- replace the component involved.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F36216 (N, A) Hub: undervoltage fault 24 V supply
Message value: %1
Message class: Supply voltage fault (undervoltage) (3)
Drive object: B_INF, HUB, VECTOR_G
Component: Terminal Board (TB) Propagation: LOCAL
Reaction: NONE (OFF1, OFF2)
Acknowledge: IMMEDIATELY (POWER ON)
Cause: The 24 V power supply on the DRIVE-CLiQ Hub Module has undershot the fault threshold.
Fault value (r0949, interpret decimal):
Actual operating voltage in 0.1 °C resolution
Remedy: - check the supply voltage of the component involved.
- replace the component involved.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
A36217 (N) Hub: undervoltage alarm 24 V supply
Message value: %1
Message class: Supply voltage fault (undervoltage) (3)
Drive object: B_INF, HUB, VECTOR_G
Component: Terminal Board (TB) Propagation: LOCAL
Reaction: NONE
Acknowledge: NONE
Cause: The 24 V power supply on the DRIVE-CLiQ Hub Module has undershot the alarm threshold.
Alarm value (r2124, interpret decimal):
Actual operating voltage in 0.1 °C resolution
Remedy: - check the supply voltage of the component involved.
- replace the component involved.
Reaction upon N: NONE
Acknowl. upon N: NONE