2 Parameters
2.2 List of parameters
SINAMICS G130/G150
732 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the GUIDs of this drive object of the Technology Extensions installed on the memory card/device memory.
r4960[0...15]: GUID of this drive object of Technology Extension 1
r4960[16]: Major information of this drive object of Technology Extension 1
r4960[17]: Minor information of this drive object of Technology Extension 1
r4960[18...33]: GUID of this drive object of Technology Extension 2
r4960[34]: Major information of this drive object of Technology Extension 2
r4960[35]: Minor information of this drive object of Technology Extension 2, ...
Dependency: Refer to: r4950, r4951, r4952, r4955, p4956, r4957, r4958, r4959
Notice: If there is no Technology Extension, then it is not possible to access an index.
Note: TEC: Technology Extension
Description: Only for service purposes.
Note: TEC: Technology Extension
Description: Displays the number of invalid Technology Extensions installed on the memory card/device memory.
Dependency: Refer to: r4976, r4978, r4979
Note: TEC: Technology Extension
Description: Displays the total length of the IDs of all the invalid Technology Extensions installed on the memory card/device
memory.
Dependency: Refer to: r4975, r4978, r4979
Note: TEC: Technology Extension
The identifier of an invalid Technology Extension comprises a maximum of 8 characters plus separator.
r4960[0...n] TEC DO-specific GUID drive object / TEC DO GUID DO
All objects Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4952 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p4961[0...n] TEC DO-specific logbook module selection / TEC DO log module
All objects Can be changed: T Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4950 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
r4975 TEC invalid number / TEC inval qty
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4976 TEC invalid identifier total length / TEC inval ID tot_l
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -