EasyManua.ls Logo

Siemens G130 - A09000 Webserver security: password for Administrator user not set; A13000 License not adequate; A13001 Error in license checksum

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1645
4 Faults and alarms
4.2 List of faults and alarms
A09000 Webserver security: password for "Administrator" user not set
Message value: -
Message class: General drive fault (19)
Drive object: All objects
Component: Control Unit (CU) Propagation: LOCAL
Reaction: NONE
Acknowledge: NONE
Cause: Webserver security: password for "Administrator" user not set
Remedy: Enter the password for user "Administrator"
A13000 License not adequate
Message value: %1
Message class: Error in the parameterization / configuration / commissioning procedure (18)
Drive object: All objects
Component: Control Unit (CU) Propagation: LOCAL
Reaction: NONE
Acknowledge: NONE
Cause: - for the drive unit, the options that require a license are being used but the licenses are not sufficient.
- an error occurred when checking the existing licenses.
Alarm value (r2124, interpret decimal):
0:
The existing license is not sufficient.
1:
An adequate license was not able to be determined as the memory card with the required licensing data was
withdrawn in operation.
2:
An adequate license was not able to be determined as there is no licensing data available on the memory card.
3:
An adequate license was not able to be determined as there is a checksum error in the license key.
4:
An internal error occurred when checking the license.
Remedy: For alarm value = 0:
Additional licenses are required and these must be activated (p9920, p9921).
For alarm value = 1:
With the system powered down, re-insert the memory card that matches the system.
For alarm value = 2:
Enter and activate the license key (p9920, p9921).
For alarm value = 3:
Compare the license key (p9920) entered with the license key on the certificate of license.
Re-enter the license key and activate (p9920, p9921).
For alarm value = 4:
- carry out a POWER ON.
- upgrade firmware to later version.
- contact Technical Support.
A13001 Error in license checksum
Message value: -
Message class: Error in the parameterization / configuration / commissioning procedure (18)
Drive object: All objects
Component: Control Unit (CU) Propagation: LOCAL
Reaction: NONE
Acknowledge: NONE
Cause: When checking the checksum of the license key, an error was detected.
Remedy: Compare the license key (p9920) entered with the license key on the certificate of license.
Re-enter the license key and activate (p9920, p9921).

Table of Contents