Siemens G130 - p1656[0...n] Current setpoint;Speed actual value filter activation; I_setp_filt act; p1657[0...n] Current setpoint filter 1 type; I_set_filt 1 type; p1658[0...n] Current setpoint filter 1 denominator natural frequency; I_set_filt1 fn_den; p1659[0...n] Current setpoint filter 1 denominator damping; I_set_filt 1 D_den

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G130/G150
436 List Manual (LH2), 07/2016, A5E03263479A
Description: Setting for activating/deactivating the current setpoint filter 1, 2 and speed actual value filter 5.
Dependency: The individual current setpoint/speed actual value filters are parameterized starting at p1657.
Note: If not all of the filters are required, then the filters should be used consecutively starting from filter 1.
Description: Sets the current setpoint filter 1 as low pass (PT2) or general 2nd order filter.
Value: 1: PT2 low pass
2: General 2nd order filter
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Note: For a general 2nd order filter, by inserting the same natural frequency in both the numerator and in the denominator,
i.e. bandstop frequency, a bandstop filter is implemented. If the numerator damping of zero is selected, the bandstop
frequency is completely suppressed.
The denominator damping can be determined from the equation for the 3 dB bandwidth:
f_3dB bandwidth = 2 * D_denominator * f_bandstop frequency
Description: Sets the denominator natural frequency for current setpoint filter 1 (PT2, general filter).
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
Description: Sets the denominator damping for current setpoint filter 1.
Dependency: The current setpoint filter 1 is activated via p1656.0 and parameterized via p1657 ... p1661.
p1656[0...n] Current setpoint/Speed actual value filter activation / I_setp_filt act
VECTOR_G (n/M) Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: DDS, p0180 Func. diagram: 4715, 6710
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0001 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Filter 1 Active Inactive -
01 Filter 2 Active Inactive -
04 Filter 5 Active Inactive -
p1657[0...n] Current setpoint filter 1 type / I_set_filt 1 type
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
1 2 1
p1658[0...n] Current setpoint filter 1 denominator natural frequency / I_set_filt1 fn_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.5 [Hz] 16000.0 [Hz] 1999.0 [Hz]
p1659[0...n] Current setpoint filter 1 denominator damping / I_set_filt 1 D_den
VECTOR_G (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 5710, 6710
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: REL Scaling: - Expert list: 1
Min Max Factory setting
0.001 10.000 0.700