SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
701
2 Parameters
2.2 List of parameters
Note: SMI: SINAMICS Sensor Module Integrated
Description: Setting to control the trace function.
Value: 0: Stop trace
1: Start trace
Index: [0] = Trace 0
[1] = Trace 1
Description: Setting to control the measurement function.
Value: 0: Stop measuring function
1: Start measuring function
2: Measuring function check parameterization
3: Start measuring function without enable signals
Description: Sets the options for the trace.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: p4700
Note: For bit 00:
0: The trace starts with p4700 as before.
1: When powering up, the trace starts immediately with the saved parameter settings with the start of the time slices.
p4700[0...1] Trace control / Trace control
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 1 0
p4701 Measuring function control / Meas fct ctrl
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 3 0
p4703[0...1] Trace options / Trace options
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Automatically start trace with time slices Yes No -